  • Description
  • Basic Info
  • Safety Info
  • MSDS
  • Price
  • Related Product
  • Supplier Reference
What is Bortezomib intermediates II

Bortezomib Intermediates II are crucial chemical compounds used in the synthesis of Bortezomib, a potent proteasome inhibitor widely employed in the treatment of multiple myeloma and mantle cell lymphoma. These intermediates play a pivotal role in the pharmaceutical manufacturing process, ensuring the production of high-quality Bortezomib with precise molecular structure and therapeutic efficacy. Designed for advanced pharmaceutical research and development, Bortezomib Intermediates II are characterized by their high purity, stability, and consistency, making them ideal for large-scale production. By facilitating the efficient synthesis of Bortezomib, these intermediates contribute to the development of life-saving therapies, supporting advancements in oncology and improving patient outcomes worldwide.

Preparation Process: The preparation of Bortezomib intermediate II involves the following steps: 1. **Protection of L-Phenylalanine**: React L-phenylalanine with benzyl chloroformate (Cbz-Cl) in the presence of a base (e.g., NaOH) to obtain Cbz-protected L-phenylalanine. 2. **Coupling with Boronic Acid Derivative**: Treat the Cbz-protected L-phenylalanine with isobutyl boronic acid using a coupling agent like HATU or DCC in the presence of a base (e.g., DIPEA) to form the boronate ester. 3. **Deprotection**: Remove the Cbz group via hydrogenolysis (H₂/Pd-C) to yield the free amine. 4. **Final Cyclization**: React the amine with pyrazine carboxylic acid under peptide coupling conditions to form the desired Bortezomib intermediate II.

Usage Scenarios: Bortezomib intermediates II are key chemical compounds used in the synthesis of Bortezomib, a proteasome inhibitor primarily employed in the treatment of multiple myeloma and mantle cell lymphoma. These intermediates serve as crucial building blocks during the drug manufacturing process, enabling the formation of the active pharmaceutical ingredient (API) with high purity and efficacy. They play a vital role in ensuring the structural integrity and biological activity of the final drug product. Additionally, these intermediates are utilized in research and development for optimizing synthetic pathways, improving yield, and reducing production costs. Their precise chemical properties make them essential for scalable and consistent pharmaceutical production.

Bortezomib intermediates II Basic Info
Chemical Name Bortezomib intermediates II
Synonyms Atrazine Impurity 11;Bortezomib intermediates I;Bortezomib Impurity 54 HCl;BortezoMib InterMediate II;Bortezomib intermediates II;BortezoMib interMediates N-2;(alphaS)-alpha-Amino-N-[(1R)-1-[(3aS,4S,6S,7aR)-hexahydro-3a,5,5-trimethyl-4,6-methano-1,3,2-benzodi;(S)-2-amino-N-((R)-3-methyl-1-((3aS,4S,6S,7aR)-3a,5,5-trimethylhexahydro-4,6-methanobenzo[d][1,3,2]dioxaborol-2-yl)butyl)-3-phenylpropanamide hydrochloride;(αS)-α-Amino-N-[(1R)-1-[(3aS,4S,6S,7aR)-hexahydro-3a,5,5-trimethyl-4,6-methano-1,3,2-benzodioxaborol-2-yl]-3-methylbutyl]-benzenepropanamide Monohydrochloride;(αS)-α-Amino-N-[(1R)-1-[(3aS,4S,6S,7aR)-hexahydro-3a,5,5-trimethyl-4,6-methano-1,3,2-benzodioxaborol-2-yl]-3-methylbutyl]-benzenepropanamide Monohydrochloride
CAS No. 205393-21-1
Molecular Formula C24H38BClN2O3
Molecular Weight 448.83412
PSA 77.07000
LogP 6.11730
Safely Info
RTECS -
Hazard Class -
Safety Statements -
HS Code -
WGK Germany -
Packing Group -
RIDADR -
Risk Statements -
Hazard Codes -
Caution Statement P264b-P271-P280-P301+P330+P331-P304+P340-P305+P351+P338-P310-P363-P390-P402-P403+P233-P406b-P501c
Hazard Declaration H290-H314
Symbol GHS05
Signal Word Warning
Bortezomib intermediates II Price
Here is a rough price range for "Bortezomib intermediates II" in the 18 countries listed. Note that these are approximate ranges and may vary based on market conditions, suppliers, and other factors:

1. **United States**: $500 - $1,500 per gram
2. **China**: $200 - $800 per gram
3. **Russia**: $300 - $900 per gram
4. **Germany**: $400 - $1,200 per gram
5. **India**: $150 - $600 per gram
6. **Japan**: $600 - $1,500 per gram
7. **Brazil**: $250 - $800 per gram
8. **South Korea**: $400 - $1,000 per gram
9. **Philippines**: No results
10. **United Kingdom**: $450 - $1,300 per gram
11. **France**: $400 - $1,200 per gram
12. **Mexico**: $200 - $700 per gram
13. **Canada**: $500 - $1,400 per gram
14. **South Africa**: No results
15. **Egypt**: No results
16. **Turkey**: $300 - $900 per gram
17. **Thailand**: No results
18. **Indonesia**: No results

If no price range is provided for a country, it means there is insufficient data or no results available for "Bortezomib intermediates II" in that market.
MSDS
SDS 1.0
Download/Modify | Technical supported by XiXisys.com. For US version, EU version (23 languages) and more, please refer to xixisys.com/en/sds/search

SAFETY DATA SHEETS

According to Globally Harmonized System of Classification and Labelling of Chemicals (GHS) - Sixth revised edition

Version: 1.0

Creation Date: Aug 12, 2017

Revision Date: Aug 12, 2017

1.Identification

1.1 GHS Product identifier

Product name N-{(1R)-3-Methyl-1-[(1S,2S,6R,8S)-2,9,9-trimethyl-3,5-dioxa-4-boratricyclo[6.1.1.02,6]dec-4-yl]butyl}-L-phenylalaninamide hydrochloride (1:1)

1.2 Other means of identification

Product number -
Other names -

1.3 Recommended use of the chemical and restrictions on use

Identified uses For industry use only.
Uses advised against no data available

1.4 Supplier's details

Company MOLBASE (Shanghai) Biotechnology Co., Ltd.
Address Floor 4 & 5, Building 12, No. 1001 North Qinzhou Road,
Xuhui District, Shanghai, China
Telephone +86(21)64956998
Fax +86(21)54365166

1.5 Emergency phone number

Emergency phone number +86-400-6021-666
Service hours Monday to Friday, 9am-5pm (Standard time zone: UTC/GMT +8 hours).

2.Hazard identification

2.1 Classification of the substance or mixture

no data available

2.2 GHS label elements, including precautionary statements

Pictogram(s) no data available
Signal word

no data available

Hazard statement(s)

no data available

Precautionary statement(s)
Prevention

no data available

Response

no data available

Storage

no data available

Disposal

no data available

2.3 Other hazards which do not result in classification

no data available

3.Composition/information on ingredients

3.1 Substances

Chemical name Common names and synonyms CAS number EC number Concentration
N-{(1R)-3-Methyl-1-[(1S,2S,6R,8S)-2,9,9-trimethyl-3,5-dioxa-4-boratricyclo[6.1.1.02,6]dec-4-yl]butyl}-L-phenylalaninamide hydrochloride (1:1) N-{(1R)-3-Methyl-1-[(1S,2S,6R,8S)-2,9,9-trimethyl-3,5-dioxa-4-boratricyclo[6.1.1.02,6]dec-4-yl]butyl}-L-phenylalaninamide hydrochloride (1:1) 205393-21-1 none 100%

4.First-aid measures

4.1 Description of necessary first-aid measures

General advice

Consult a physician. Show this safety data sheet to the doctor in attendance.

If inhaled

If breathed in, move person into fresh air. If not breathing, give artificial respiration. Consult a physician.

In case of skin contact

Wash off with soap and plenty of water. Consult a physician.

In case of eye contact

Rinse thoroughly with plenty of water for at least 15 minutes and consult a physician.

If swallowed

Never give anything by mouth to an unconscious person. Rinse mouth with water. Consult a physician.

4.2 Most important symptoms/effects, acute and delayed

no data available

4.3 Indication of immediate medical attention and special treatment needed, if necessary

no data available

5.Fire-fighting measures

5.1 Extinguishing media

Suitable extinguishing media

Use water spray, alcohol-resistant foam, dry chemical or carbon dioxide.

5.2 Specific hazards arising from the chemical

no data available

5.3 Special protective actions for fire-fighters

Wear self-contained breathing apparatus for firefighting if necessary.

6.Accidental release measures

6.1 Personal precautions, protective equipment and emergency procedures

Use personal protective equipment. Avoid dust formation. Avoid breathing vapours, mist or gas. Ensure adequate ventilation. Evacuate personnel to safe areas. Avoid breathing dust. For personal protection see section 8.

6.2 Environmental precautions

Prevent further leakage or spillage if safe to do so. Do not let product enter drains. Discharge into the environment must be avoided.

6.3 Methods and materials for containment and cleaning up

Pick up and arrange disposal. Sweep up and shovel. Keep in suitable, closed containers for disposal.

7.Handling and storage

7.1 Precautions for safe handling

Avoid contact with skin and eyes. Avoid formation of dust and aerosols. Avoid exposure - obtain special instructions before use.Provide appropriate exhaust ventilation at places where dust is formed. For precautions see section 2.2.

7.2 Conditions for safe storage, including any incompatibilities

Store in cool place. Keep container tightly closed in a dry and well-ventilated place.

8.Exposure controls/personal protection

8.1 Control parameters

Occupational Exposure limit values

no data available

Biological limit values

no data available

8.2 Appropriate engineering controls

Handle in accordance with good industrial hygiene and safety practice. Wash hands before breaks and at the end of workday.

8.3 Individual protection measures, such as personal protective equipment (PPE)

Eye/face protection

Safety glasses with side-shields conforming to EN166. Use equipment for eye protection tested and approved under appropriate government standards such as NIOSH (US) or EN 166(EU).

Skin protection

Wear impervious clothing. The type of protective equipment must be selected according to the concentration and amount of the dangerous substance at the specific workplace. Handle with gloves. Gloves must be inspected prior to use. Use proper glove removal technique(without touching glove's outer surface) to avoid skin contact with this product. Dispose of contaminated gloves after use in accordance with applicable laws and good laboratory practices. Wash and dry hands. The selected protective gloves have to satisfy the specifications of EU Directive 89/686/EEC and the standard EN 374 derived from it.

Respiratory protection

Wear dust mask when handling large quantities.

Thermal hazards

no data available

9.Physical and chemical properties

Physical state no data available
Colour no data available
Odour no data available
Melting point/ freezing point 197-198ºC
Boiling point or initial boiling point and boiling range no data available
Flammability no data available
Lower and upper explosion limit / flammability limit no data available
Flash point no data available
Auto-ignition temperature no data available
Decomposition temperature no data available
pH no data available
Kinematic viscosity no data available
Solubility no data available
Partition coefficient n-octanol/water (log value) no data available
Vapour pressure no data available
Density and/or relative density no data available
Relative vapour density no data available
Particle characteristics no data available

10.Stability and reactivity

10.1 Reactivity

no data available

10.2 Chemical stability

Stable under recommended storage conditions.

10.3 Possibility of hazardous reactions

no data available

10.4 Conditions to avoid

no data available

10.5 Incompatible materials

no data available

10.6 Hazardous decomposition products

no data available

11.Toxicological information

Acute toxicity

  • Oral: no data available
  • Inhalation: no data available
  • Dermal: no data available

Skin corrosion/irritation

no data available

Serious eye damage/irritation

no data available

Respiratory or skin sensitization

no data available

Germ cell mutagenicity

no data available

Carcinogenicity

no data available

Reproductive toxicity

no data available

STOT-single exposure

no data available

STOT-repeated exposure

no data available

Aspiration hazard

no data available

12.Ecological information

12.1 Toxicity

  • Toxicity to fish: no data available
  • Toxicity to daphnia and other aquatic invertebrates: no data available
  • Toxicity to algae: no data available
  • Toxicity to microorganisms: no data available

12.2 Persistence and degradability

no data available

12.3 Bioaccumulative potential

no data available

12.4 Mobility in soil

no data available

12.5 Other adverse effects

no data available

13.Disposal considerations

13.1 Disposal methods

Product

The material can be disposed of by removal to a licensed chemical destruction plant or by controlled incineration with flue gas scrubbing. Do not contaminate water, foodstuffs, feed or seed by storage or disposal. Do not discharge to sewer systems.

Contaminated packaging

Containers can be triply rinsed (or equivalent) and offered for recycling or reconditioning. Alternatively, the packaging can be punctured to make it unusable for other purposes and then be disposed of in a sanitary landfill. Controlled incineration with flue gas scrubbing is possible for combustible packaging materials.

14.Transport information

14.1 UN Number

ADR/RID: no data available IMDG: no data available IATA: no data available

14.2 UN Proper Shipping Name

ADR/RID: no data available
IMDG: no data available
IATA: no data available

14.3 Transport hazard class(es)

ADR/RID: no data available IMDG: no data available IATA: no data available

14.4 Packing group, if applicable

ADR/RID: no data available IMDG: no data available IATA: no data available

14.5 Environmental hazards

ADR/RID: no IMDG: no IATA: no

14.6 Special precautions for user

no data available

14.7 Transport in bulk according to Annex II of MARPOL 73/78 and the IBC Code

no data available

15.Regulatory information

15.1 Safety, health and environmental regulations specific for the product in question

Chemical name Common names and synonyms CAS number EC number
N-{(1R)-3-Methyl-1-[(1S,2S,6R,8S)-2,9,9-trimethyl-3,5-dioxa-4-boratricyclo[6.1.1.02,6]dec-4-yl]butyl}-L-phenylalaninamide hydrochloride (1:1) N-{(1R)-3-Methyl-1-[(1S,2S,6R,8S)-2,9,9-trimethyl-3,5-dioxa-4-boratricyclo[6.1.1.02,6]dec-4-yl]butyl}-L-phenylalaninamide hydrochloride (1:1) 205393-21-1 none
European Inventory of Existing Commercial Chemical Substances (EINECS) Not Listed.
EC Inventory Not Listed.
United States Toxic Substances Control Act (TSCA) Inventory Not Listed.
China Catalog of Hazardous chemicals 2015 Not Listed.
New Zealand Inventory of Chemicals (NZIoC) Not Listed.
Philippines Inventory of Chemicals and Chemical Substances (PICCS) Not Listed.
Vietnam National Chemical Inventory Not Listed.
Chinese Chemical Inventory of Existing Chemical Substances (China IECSC) Not Listed.

16.Other information

Information on revision

Creation Date Aug 12, 2017
Revision Date Aug 12, 2017

Abbreviations and acronyms

  • CAS: Chemical Abstracts Service
  • ADR: European Agreement concerning the International Carriage of Dangerous Goods by Road
  • RID: Regulation concerning the International Carriage of Dangerous Goods by Rail
  • IMDG: International Maritime Dangerous Goods
  • IATA: International Air Transportation Association
  • TWA: Time Weighted Average
  • STEL: Short term exposure limit
  • LC50: Lethal Concentration 50%
  • LD50: Lethal Dose 50%
  • EC50: Effective Concentration 50%

References

  • IPCS - The International Chemical Safety Cards (ICSC), website: http://www.ilo.org/dyn/icsc/showcard.home
  • HSDB - Hazardous Substances Data Bank, website: https://toxnet.nlm.nih.gov/newtoxnet/hsdb.htm
  • IARC - International Agency for Research on Cancer, website: http://www.iarc.fr/
  • eChemPortal - The Global Portal to Information on Chemical Substances by OECD, website: http://www.echemportal.org/echemportal/index?pageID=0&request_locale=en
  • CAMEO Chemicals, website: http://cameochemicals.noaa.gov/search/simple
  • ChemIDplus, website: http://chem.sis.nlm.nih.gov/chemidplus/chemidlite.jsp
  • ERG - Emergency Response Guidebook by U.S. Department of Transportation, website: http://www.phmsa.dot.gov/hazmat/library/erg
  • Germany GESTIS-database on hazard substance, website: http://www.dguv.de/ifa/gestis/gestis-stoffdatenbank/index-2.jsp
  • ECHA - European Chemicals Agency, website: https://echa.europa.eu/

Disclaimer: The above information is believed to be correct but does not purport to be all inclusive and shall be used only as a guide. The information in this document is based on the present state of our knowledge and is applicable to the product with regard to appropriate safety precautions. It does not represent any guarantee of the properties of the product. We as supplier shall not be held liable for any damage resulting from handling or from contact with the above product.
Bortezomib intermediates II Suppliers
Company Name
Business Type
Location
Details
Request For Quotation
Request For Quotation